Model No. 2 DM 1

TWO VALVE MANIFOLD SINGLE ISOLATE / VENT BLOCK DIRECT MOUNTING TYPE

DESCRIPTION
Designed for low pressure application and level measurement on atmospheric tanks with differential pressure transmiters.

Isolate valve with T-bar handle
Vent valve with anti tamper handle.
ConnectionsProcess       : 1/4"NPT (F) / 1/4" BSPT (F) / 10 mm OD
Instrument  : Flanged
Drain / Vent : 1/4"NPT (F) / 1/4" BSPT (F) / 10 mm OD
Test Pressure@ 25° C Room Temperature
Hydrostatic   : Body - 620 Kg/cm2
                     Seat - 413 Kg/cm2
Pneumatic    : Seat - 40 Kg/cm2
Gland packing PTFE : Standard
GRAPHOIL : Temperatures above 180°C
Material A 105, A 182 Gr F 304SS, A 182 Gr F 316SS, Monel, Hastelloy
FinishCS : Zinc Plated and Dichromated; SS : Natural
AccessoryMounting Bolts - IS : 1364 - 1960 - 4 Nos
Interface seal - PTFE / VITO 'N' - 2 Nos